Transformers have been a central main pillar of Tralec for a long time. The Tralec GmbH which emerged from AWEH Kirchner crafts transformers, chokes, spools and winding goods of all sorts on behalf of our customers for more than 40 years. Beside our experts for calculation and design of our products we can fall back upon many years of experience to manufacture a product that will satisfy your demands.
|
|
Corona Transformers
We produce customised transformers for well-known manufacturer of Corona-Stations. They were used to roughening the surface of synthetic material using high voltage. Our Corona Transformers have following features:
- One-Phase Transformer
- Oil-immersed transformer
- Power range up to 60 kVA
- Voltage range up to 25 kV
- Frequency range 10 - 30 kHz
|
Power Transformers
There are various numbers of applications of Power Transformers. On behalf of our customers we manufacture power transformers with following features:
- One-phase transformers or Three-phase transformers
- Dry model with separated windings
- Basic insulation against electric shocks
- Power range: Single phase up to 25 kVA / Three-phase up to 40 kVA
- Input voltage range: Up to 1000 V
- Output voltage range: 50 - 1000 V
- Frequency range: Up to 50 - 60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-1
|
Isolating Transformers
Isolating Transformers are used, if there's a need for double or stronger high electric insulation.
We offer you isolating transformers with following features:
- One-phase transformers or Three-phase transformers
- Dry model with separated windings
- Protective separation between input and output windings
- Power range: Single phase up to 25 kVA / Three-phase up to 40 kVA
- Input voltage range: Up to 1000 V
- Output voltage range: 50 - 1000 V
- Frequency range: Up to 50-60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-4
|
|
Isolating Transformers for medical devices
This special transformer is used to ensure the energy supply in medical rooms and medical devices. Our products have following features:
- One-phase transformers or Three-phase transformers
- Dry model with separated windings
- Power range: 2,5 - 10 kVA
- Inrush curren: Up to 12 fold
- No load current: Maximum 3%
- Input voltage range: Up to 1000 V
- Output voltage range: Up to 250 V
- Frequency range: Up to 50 - 60Hz
- Integrated temperature sensor
- Static screen
- Insulation monitoring
- Compliant with VDE 0570 / DIN EN 61558-2-15
|
|
Safety Isolating Transformers
Isolating Transformers are used, if there's a need for double or stronger high electric insulation and touchability can not be excluded. Our Safety Isolating Transformers have following features:
- One-phase transformers or Three-phase transformers
- Dry model with separated windings
- Protective separation between input and output windings
- power range: One-phase up to 25 kVA / Three-phase up to 40 kVA
- Input voltage range: Up to 1000 V
- Output voltage range: Up to 50 V
- Frequency range: Up to 50 - 60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-6
|
|
Autotransformers
You can use Autotransformers if the power supply voltage should be adjusted to the accommodative device. Our autotransformers have following features:
- One-phase transformers or Three-phase transformers
- Dry model with shared windings
- Power range: One-phase up 20 kVA / Three-phase up to 100 kVA
- Input power range: Up to 1000 V
- Output power range: Up to 1000 V
- Frequency range: Up to 50 - 60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-13
|
|
Control Transformers
Control Transformers appear in a various number of application. On behalf of our customers we
manufacture Control Transformers, conform to norms with following features:
- One-phase transformer
- Dry model with separated windings
- basic insulation against electric shocks
- Power range: Up to 10 kVA
- Input power range: Up to 1000 V
- Output power range: Up to 250 V
- Frequency range: Up to 50 - 60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-12
|
|
Converter Transformers
Converter Transformers are used to change an AC voltage into a DC voltage.
Our transformers have following features:
- Dry model with separated windings
- Protective separation between input and output windings
- Power range: One-phase up to 25 kVA / Three-phase up to 40 kVA
- Input voltage range: Up to 1000 V
- Output voltage range: 50 - 1000 V
- Frequency range: up to 500 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-4
|
|
Toroidal Transformers
Toroidal Transformers are in use, if a high efficiency and a compact design are more important than a low priced assembling. On behalf of our customers we manufacture Toroidal Transformers conform to norms with following features:
- One-phase transformers or Three-phase transformers
- Dry model with separated windings
- Protective separation between input and output windings
- Power range: One-phase up to 25 kVA / Three-phase up to 40 kVA
- Input voltage range: Up to 500 V
- Output voltage range: 12 - 1000 V
- Frequency range: 50 - 60 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-4/6
|
|
Starting Transformers
Starting Transformers are used to lower the voltage while starting hugh electric motors and therewith lower the starting currents. Our Starting Transformers have following features:
- One-phase transformers or Three-phase transformers
- Dry model with shared windings
- Power range: One-phase up to 20 kVA / Three-phase up to 100 kVA
- Input voltage range: Up to 1000 V
- Output voltage range: Up to 1000 V
- Compliant with VDE 0532 / DIN EN 60076
|
|
Smoothing Chokes/ DC Chokes
Smoothing Chokes are used and appear in various numbers of applications. We manufacture customised Smoothing Chokes conform to norms with following features:
- One-phase transformers or Three-phase chokes
- Dry model
- Power range: One-phase up to 20 kVA
- Voltage range: Up to 1000 V
- Ripple W: up to 15%
- Ripple-Frequency: Up to 300 Hz
- Compliant with VDE 0570 / DIN EN 61558-2-20
|
|
Commutation Inductors
Commutation Inductors/DC Chokes cause a delay of the slope control during the electric torque.
Our Commutation Inductors have following features:
- One-phase transformers or Three-phase chokes
- Dry model
- Power range: One-phase up to 10 kVA / Three-phase up to 15 kVA
- Voltage range: Up to 1000 V
- Frequency range: 50/60 Hz
- Nominal voltage drop UC: 4%
- Compliant with VDE 0570 / DIN EN 61558-2-20
|
|
Zero Point Chokes
Zero Point Chokes reduce the ripple current in a neutral conductor. Our Zero Point Chokes have following features:
- One-phase transformers or Three-phase chokes
- Dry model
- Power range: One-phase up to 20 kVA / Three-phase up to 35 kVA
- Voltage range: Up to 1000 V
- Frequency range: Up to 1 Mhz
- Compliant with VDE 0570 / DIN EN 61558-2-20
|
|
Aerator transformer
A variable voltage is used to variate the engine speed of an aerator. The transformer for this usage (type EVTL and DVTL)are equipped with several secondary extractions, therefore you could adjust the engine speed of one-phase and three-phaseAC motors in different steps.
- One-phase (EVTL) or Three-phase (DVTL) transformers
- Power range: One-phase 360-3600 VA / Three-phase 540- 10 kVA
- Input voltage range: One-phase 230 V / Three-phase 3x400 V
- Output voltgae range: One-phase 80-230 V / Three-phase 3x140-400 V
- Frequency range: 50/60 Hz
- Compliant with VDE 0550
|
|
|
Do you have any questions or need information about product in the field of transformers?
Don't hesitate to contact us!
Mr. Duewel is pleased to answer your questions via email or by phone at +49 - 040 - 727 57 235.
|